Lumeta can now provide/exchange data with a BlueCat Address Manager (BAM) connected to a BlueCat Gateway. (BG)
About Integration
Purpose | API | Payload | Response |
---|---|---|---|
Gateway Authentication | https://172.18.1.123/rest_login curl -v -H "Accept: application/json" -H 'Content-type: | { "username" : "gateway", | { |
Get list of networks/configurations | lumeta/getnetworklist curl -X GET \ -H 'Accept: application/json' \ -H 'Auth: Basic I6vp7MTU3Mjg4MjM2NzU5NjpnYXRld2F5' | None | [{"id":100880,"name":"Somerset","type":"Configuration","properties":null}] |
Get list of devices | lumeta/getiplist \ It retrieves devices for all networks curl -X GET \ -H 'Auth: Basic O2MsBMTU3Mjg4NTI2MDUwMDpnYXRld2F5' \ | None | [{"config_id":100880,"config_name":"Somerset","id":100895,"ip_address":"172.18.1.1","properties":{"address":"172.18.1.1","locationCode":"US MOO","locationInherited":"true","state":"GATEWAY"}},{"config_id":100880,"config_name":"Somerset","id":100901,"ip_address":"172.18.1.37","properties":{"address":"172.18.1.37","locationCode":"US MOO","locationInherited":"true","state":"STATIC"}},{"config_id":100880,"config_name":"Somerset","id":100902,"ip_address":"172.18.1.42","properties":{"address":"172.18.1.42","locationCode":"US MOO","locationInherited":"true","state":"STATIC"}}] |
Add list of devices | http://172.18.1.123/lumeta/addiplist curl -X POST \ | array of configuration with each configuration containing list of devices that need to be added [{"config_name": "Somerset", | { |
Create configuration screen under Integrations for BlueCat -
A new page will be created under Settings→Integration for BlueCat Integration
Configuration page will be added under "Other Solutions" and include below details
Feed Interval
Server IP/DNS name
User name
Password
Option to add unmanaged devices with no network block defined
Just like Qualys integration, when user enters credential for BlueCat server, an API call would be made to retrieve list of configurations. Configuration name would be displayed against zone where user can map a particular zone to a particular configuration. If a Zone is enabled, but no configuration name is selected, it would get devices for all the configurations
Add unmanaged devices with no network block defined
If selected, this option would create block and network for devices that are not in any of the existing blocks. If not selected, it would not create devices in BAM where there is no container block existing for this device
Select asset mapping by configuration
Option | Behavior |
---|---|
No zones are enabled | No assets will be pushed to BAM |
One zone is enabled however, no configuration is selected under BlueCat Configuration Name | User has to select a configuration in order to push assets to BAM. No assets will be pushed to BAM |
One zone and one configuration is selected | Lumeta would identify all ip addresses discovered under selected zone and add ip addresses under selected configuration |
Two zones and two configurations are selected | Lumeta would identify all ip addresses discovered under selected zones and add ip addresses under selected configuration for the ip address that don't exist in selected configuration for that zone |
CLI
API
Attribute | value | Data Point in Lumeta | Note | Sample Value |
---|---|---|---|---|
Data point that Lumeta has
ManuLife has identified this integration as a business need. Other customers have asked in the past, but we now have a point of contact to work with from BlueCat.
# | Title | User Story | Importance | Notes |
---|
Connect to the management server | Use Lumeta to retrieve information from the server via API | Must Have |
|
Configuration | Configuration will be implemented in Integrations section of the application. | Must Have |
Configuration screen | This screen will allow the user to input needed configuration values to connect to and poll the BlueCat management server (server, credentials, polling interval) | Must Have |
Configuration form input validation | All fields need to perform input validation to ensure proper input types. Form fields need to be able to support input as required and allowed by BlueCat management server in terms of characters allowed/disallowed, string size limits, etc. | Must Have |
Connection Status UI | Visual indicator showing connection status (connected / Disconnected). | Must Have |
Test Connection Status UI | There will be a "Test Configuration" button to verify connectivity on demand. This button should return either a a positive result or the the best available error message to help the user trouble shoot the connection. | Must Have |
CLI configuration commands | BlueCat connection must be able to be configured, tested, and enabled via the CLI | Must Have |
Discovery | Use the BlueCat API capability to retrieve information from the management station (network, device, interface) | May be possible Phase II effort |
Logging | At log level "info" system should log successful poll or error message, time of poll, At log level "debug: system should log successful poll or error message, time of poll, size of response in bytes | Must Have |
Dashboard | New dashboard will be created for this feature and added to the Integrations category | Must Have |
Widget | Standard implementation :
| Must Have |
Data Management | Each polled response, when not an error or empty response, will replace the previous existing set of devices/information. |
- LUM-662Getting issue details... STATUS
Key | Summary | T | Assignee | Status | Resolution | qa assignee |
---|
Milestone | Date Complete | Notes |
---|---|---|
SPIKE Requirements:
| ||
QA Review:
| ||
QA Meeting:
| ||
Feature Demo for Product owner |
Below is a list of questions to be addressed as a result of this requirements document:
Question | Outcome |
---|---|