Here's one This 14-second video steps illustrates one way to identify a "leaker" from Spectre Portal 3.3 and later.https://goo.gl/d6DKYAinvestigate a leaking device from the Lumeta 3.3 Portal.  A larger, higher-resolution view of the same is available here.

Image Added

The step-by-step procedure is here:

  1. Let's assume you notice the Command Center on your Lumeta Portal beaconing a warning.Image Added

  2. You open the notifications window to see what warnings have been issued.  Several leaks have been found. You open the link for the first leaking IP address.
    Image Added

  3. By following that link, you navigate to the device's location in its zone map and can also see that the device is active.
    Image Added


  4. Right-click on the device to look more closely at its details.
    Image Added

  5. On the Leak Response tab, we learn that device 65.246.244.92 has both an inbound and an outbound leak path over Port 80.
    Image Added

  6. On the Notifications tab, we learn the time and date of when the device was found to be leaking.
    Image Added